Skip to main navigation Skip to search Skip to main content

动态脊柱支撑机器人评测脊髓损伤患者坐位躯干控制的信度与效度研究

Translated title of the contribution: Reliability and validity of the robotic brace for dynamic trunk support system for trunk control function assessment in patients with spinal cord injury
  • Jiehong Shi
  • , Rongli Wang
  • , Ninghua Wang
  • , Xingzhao Guo
  • , Zhihao Zhou
  • , Qining Wang
  • Peking University

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: To investigate the test- retest reliability and criterion validity of the Robotic Brace for Dynamic Trunk Support System (RoboBDsys) in evaluating seated trunk control function in patients with spinal cord injury (SCI). Method: From October to December, 2022, 20 patients with spinal cord injury who were unable to walk were recruited. All participants completed RoboBDsys trunk control test including static control test and dynamic control test on the seated platform. The evaluation indexes were the supporting torque regression slope exerted by the robot platform on the direction of x, y, α, and θ, recorded as Kx, Ky, Kθ, Kα; the average supporting torque recorded as Fx, Fy, Mθ, Mα in the static control test;and the the Range of Motion (ROM) of trunk in four directions in the dynamic control test. All the participants completed Trunk Control Test (TCT) as criterion assessment. The test interval was one week, intraclass correlation coefficient(ICC) values were calculated between two RoboBDsys trunk control test. Result: There were 13 participants completed two tests. In the static control test, the ICCs of four indexes were 0.418—0.742 between 2 tests; the ICCs of all indexes in dynamic control test were 0.633—0.848, which all showed moderate to high test-retest reliability. In regards of criterion validity, there was low to moderate correlation between Ky, Mθ, Mα in static control test and TCT (|r|=0.467—0.561, P<0.05);all indexes except right lateral flection ROM in dynamic control test showed moderate to high correlation with TCT (r= 0.559—0.758, P<0.05). Conclusion: RoboBDsys is a reliable and valid tool for evaluating seated trunk control function in patients with SCI.

Translated title of the contributionReliability and validity of the robotic brace for dynamic trunk support system for trunk control function assessment in patients with spinal cord injury
Original languageChinese (Traditional)
Pages (from-to)1643-1650
Number of pages8
JournalChinese Journal of Rehabilitation Medicine
Volume38
Issue number12
DOIs
StatePublished - Dec 2023
Externally publishedYes

Fingerprint

Dive into the research topics of 'Reliability and validity of the robotic brace for dynamic trunk support system for trunk control function assessment in patients with spinal cord injury'. Together they form a unique fingerprint.

Cite this