跳到主要导航 跳到搜索 跳到主要内容

A Low-Cost Flexible Perforated Respiratory Sensor Based on Platinum for Continuous Respiratory Monitoring

  • Lu Cao
  • , Zhitong Zhang
  • , Junshi Li
  • , Zhongyan Wang
  • , Yingjie Ren
  • , Qining Wang
  • , Dong Huang
  • , Zhihong Li
  • National Key Laboratory of Science and Technology on Micro/Nano Fabrication
  • Peking University

科研成果: 期刊稿件文章同行评审

17 引用 (Scopus)

摘要

Monitoring sleep conditions is of importance for sleep quality evaluation and sleep disease diagnosis. Accurate respiration detection provides key information about sleep conditions. Here, we propose a perforated temperature sensor that can be worn below the nasal cavity to monitor breath. The sensing system consists of two perforated temperature sensors, signal conditioning circuits, a transmission module, and a supporting analysis algorithm. The perforated structure effectively enhances the sensitivity of the system and shortens the response time. The sensor’s response time is 0.07 s in air and sensitivity is 1.4‰°C−1. The device can achieve a monitoring respiratory temperature range between normal room temperature and 40 °C. The simple and standard micromachining process ensures low cost and high reproducibility. We achieved the monitoring of different breathing patterns, such as normal breathing, panting, and apnea, which can be applied to sleep breath monitoring and exercise information recording.

源语言英语
文章编号1743
期刊Micromachines
13
10
DOI
出版状态已出版 - 10月 2022
已对外发布

指纹图谱

探究 'A Low-Cost Flexible Perforated Respiratory Sensor Based on Platinum for Continuous Respiratory Monitoring' 的科研主题。它们共同构成独一无二的学术指纹。

引用此