摘要
Electrochemiluminescence (ECL) of luminol is a well-established methodology in analytical chemistry and bioimaging. Developing novel strategies to enhance the ECL signal of this model emitter is a challenging but rewarding task. In this work, we introduced the high-intensity focused ultrasound (HIFU), as a pretreatment means and a non-invasive way to trigger and boost the ECL signal with a 40-fold significant enhancement in the luminol-O2 system without the addition of exogenous co-reactants. The superoxide anion (O2−•) generated in situ by HIFU was the key initiator for boosting the ECL emission as demonstrated in this study for the first time. This promising co-reactant-free strategy could find potential applications for ultrasensitive ECL detection in the analysis of complex biological entities. Graphical abstract: [Figure not available: see fulltext.]
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 8309-8315 |
| 页数 | 7 |
| 期刊 | Analytical and Bioanalytical Chemistry |
| 卷 | 414 |
| 期 | 29-30 |
| DOI | |
| 出版状态 | 已出版 - 12月 2022 |
| 已对外发布 | 是 |