跳到主要导航 跳到搜索 跳到主要内容

Impact of electrode positions and harmonic frequency components in SSVEP-based BCIs

  • The University of Auckland

科研成果: 期刊稿件文章同行评审

2 引用 (Scopus)

摘要

Steady state visual evoked potential (SSVEP) based brain computer interfaces (BCIs) have been recognised as having major potential to be used practically in everyday daily life as they typically outperform more traditional BCIs in terms of detection accuracy and information transfer rates. It is also essential to improve the ease of use such as reducing the number of necessary electrodes without decreasing speed or accuracy. This study investigated the extent to which electrode positions, derivation methods, and harmonics will affect the performance of a SSVEP-based BCI. A pilot study was carried out on a 4-class SSVEP-based BCI with six healthy subjects. Detection accuracy increased from 63.75 ± 5.62% (mean ± SD) with monopolar derivation to 89.42 ± 5.58% with two-channel bipolar derivation using only harmonic H1. The significantly improved detection accuracy with two electrodes implies that it is possible to achieve high classification accuracy with a very low number of electrodes.

源语言英语
页(从-至)168-184
页数17
期刊International Journal of Intelligent Systems Technologies and Applications
14
2
DOI
出版状态已出版 - 2015
已对外发布

指纹图谱

探究 'Impact of electrode positions and harmonic frequency components in SSVEP-based BCIs' 的科研主题。它们共同构成独一无二的学术指纹。

引用此